Home › MCQs › Urinalysis & Body Fluids › Urine chemical (dipstick)

Urinalysis & Body Fluids: Urine chemical (dipstick)

49 Urinalysis & Body Fluids MCQs on Urine chemical (dipstick) with answers and explanations.

123
Q1EasyUrine chemical (dipstick)

A random urine sample from a healthy adult on a mixed diet typically has a pH of about:

Answer: B. 6.0

Urine pH normally ranges 4.5–8.0 and averages about 6.0 because the kidney excretes the daily acid load. A pH of 9 suggests an old sample with urease-producing bacteria.

ID LG-CHE-0123 · Found a mistake? Report it
Q2EasyUrine chemical (dipstick)

Which sugar gives a negative copper-reduction (Benedict) test in urine?

Answer: B. Sucrose

Sucrose has no free anomeric carbon, so it is non-reducing. Fructose, galactose and arabinose are reducing sugars and give a positive result.

ID LG-PAR-0330 · Found a mistake? Report it
Q3EasyUrine chemical (dipstick)

The reagent strip protein pad is based on which principle?

Answer: D. Protein error of indicators

At a fixed pH of about 3, the indicator (tetrabromphenol blue) changes colour when protein, mainly albumin, accepts hydrogen ions. This is the protein error of indicators.

ID MG-UBF-0042 · Found a mistake? Report it
Q4EasyUrine chemical (dipstick)

The glucose pad on a reagent strip uses which enzyme system?

Answer: B. Glucose oxidase and peroxidase

Glucose oxidase produces hydrogen peroxide, which peroxidase uses to oxidise a chromogen. The reaction is specific for glucose.

ID MG-UBF-0044 · Found a mistake? Report it
Q5EasyUrine chemical (dipstick)

A patient with hemolytic anemia is expected to have:

Answer: A. Negative urine bilirubin and increased urobilinogen

Excess unconjugated bilirubin is not water-soluble and does not appear in urine, but more is converted to urobilinogen in the gut and excreted in urine.

ID MG-UBF-0052 · Found a mistake? Report it
Q6EasyUrine chemical (dipstick)

A urine sample left uncovered at room temperature and in light for several hours may give a false-negative result for:

Answer: B. Bilirubin

Bilirubin is photo-oxidised to biliverdin on exposure to light, which does not react on the pad. Urobilinogen is also unstable and oxidises to urobilin.

ID MG-UBF-0054 · Found a mistake? Report it
Q7EasyUrine chemical (dipstick)

A urine specimen kept at room temperature for 6 hours before testing will most likely show:

Answer: B. Increased pH and decreased glucose

Bacteria multiply, consume glucose and produce ammonia from urea, raising pH. Casts and cells may also lyse. Urine should be tested within 2 hours or refrigerated.

ID MG-UBF-0059 · Found a mistake? Report it
Q8EasyUrine chemical (dipstick)

The reagent strip blood pad detects hemoglobin through:

Answer: A. Pseudoperoxidase activity of heme

Heme has peroxidase-like activity that breaks down the pad's hydrogen peroxide and oxidises a chromogen. Strong oxidising contaminants such as bleach can therefore cause false-positive results.

ID MG-UBF-0061 · Found a mistake? Report it
Q9EasyUrine chemical (dipstick)

Which reagent strip pad requires the longest reaction time, about 2 minutes, before reading?

Answer: B. Leukocyte esterase

The leukocyte esterase reaction is slow and is read at about 2 minutes; most other pads are read between 30 and 60 seconds.

ID MG-UBF-0134 · Found a mistake? Report it
Q10EasyUrine chemical (dipstick)

The nitrite pad of a reagent strip is based on which reaction?

Answer: D. Griess reaction: diazotisation followed by coupling to form a pink azo dye

Nitrite reacts with an aromatic amine to form a diazonium salt, which couples with a second compound to give a pink colour. Peroxidase activity is the basis of the blood pad.

ID MG-UBF-0136 · Found a mistake? Report it
Q11EasyUrine chemical (dipstick)

The reagent strip pH pad uses a double indicator system of:

Answer: D. Methyl red and bromthymol blue

Methyl red and bromthymol blue give a colour range from orange to blue across pH 5 to 9. Tetrabromphenol blue is the protein pad indicator.

ID MG-UBF-0142 · Found a mistake? Report it
Q12EasyUrine chemical (dipstick)

Which reagent strip technique is correct?

Answer: A. Dip briefly, then remove excess urine by touching the edge to the container

The strip is dipped briefly so all pads are wet, and excess is removed to prevent run-over. Prolonged dipping leaches reagents from the pads.

ID MG-UBF-0144 · Found a mistake? Report it
Q13EasyUrine chemical (dipstick)

The reagent strip protein pad is most sensitive to which protein?

Answer: A. Albumin

The protein-error-of-indicators pad reacts mainly with albumin and is much less sensitive to globulins and free light chains (Bence Jones protein).

ID MG-EUA-0001 · Found a mistake? Report it
Q14EasyUrine chemical (dipstick)

A positive nitrite test on a reagent strip indicates:

Answer: B. Bacteria that reduce nitrate to nitrite, such as E. coli

Many Gram-negative urinary pathogens, especially Enterobacterales such as E. coli, reduce dietary nitrate to nitrite, so a positive nitrite suggests bacteriuria.

ID MG-EUA-0002 · Found a mistake? Report it
Q15EasyUrine chemical (dipstick)

Which urine specimen is preferred for routine urinalysis because it is the most concentrated?

Answer: C. First morning specimen

The first morning urine has been in the bladder overnight, so it is concentrated and best for detecting substances and formed elements present in small amounts.

ID MG-EUA-0003 · Found a mistake? Report it
Q16EasyUrine chemical (dipstick)

How should urine reagent strips be stored?

Answer: D. In the original tightly capped container at room temperature, away from moisture and light

Moisture, light, heat and volatile chemicals damage the reagent pads. Strips are kept in their capped container with desiccant and are not refrigerated or frozen.

ID MG-EUA-0004 · Found a mistake? Report it
Q17EasyUrine chemical (dipstick)

In a healthy adult, the reagent strip glucose result is normally:

Answer: A. Negative

Filtered glucose is almost completely reabsorbed by the proximal tubule, so normal urine gives a negative glucose pad.

ID MG-EUA-0005 · Found a mistake? Report it
Q18EasyUrine chemical (dipstick)

In healthy people, the urine urobilinogen result on a reagent strip is usually:

Answer: B. Present in a small normal amount (about 1 mg/dL or less)

Some urobilinogen formed in the gut is reabsorbed and excreted in urine, so a small amount (up to about 1 mg/dL, 1 EU) is normal. Strips cannot reliably detect its absence.

ID MG-EUA-0006 · Found a mistake? Report it
Q19EasyUrine chemical (dipstick)

Which substances can give a positive reagent strip blood pad?

Answer: C. Intact red cells, free hemoglobin and myoglobin

The blood pad uses the pseudoperoxidase activity of heme, which is present in hemoglobin (free or in red cells) and in myoglobin.

ID MG-EUA-0007 · Found a mistake? Report it
Q20MediumUrine chemical (dipstick)

A false-negative nitrite test in a patient with a UTI is most likely when:

Answer: B. The urine stayed in the bladder for less than 4 hours or the organism does not reduce nitrate

Bacteria need about 4 hours in the bladder to convert nitrate to nitrite, and Enterococcus and yeasts do not. A first morning sample is best. Standing at room temperature can cause false positives.

ID MG-UBF-0005 · Found a mistake? Report it
123
📱 Practise with a timer, track your score and earn certificates in the free MLT Globe app – Google Play or practise online.