Histopathology: Lab safety, equipment & museum

20 Histopathology MCQs on Lab safety, equipment & museum with answers and explanations.

Q1EasyLab safety, equipment & museum

Disposable latex or nitrile gloves mainly protect lab staff from:

Answer: B. Skin contact with blood and body fluids

Gloves are a barrier to fluid contact; they do not resist sharps, and aerosols need respiratory protection or a safety cabinet.

ID LG-HIS-0007 · Found a mistake? Report it
Q2EasyLab safety, equipment & museum

What is the main safety hazard of picric acid?

Answer: D. It can explode when allowed to dry out

Dry picric acid is shock-sensitive and explosive, so it is stored moist with water.

ID LG-HIS-0111 · Found a mistake? Report it
Q3EasyLab safety, equipment & museum

Which step is essential when picking sections up on slides?

Answer: A. Each slide carries the block's identification number

Correct labelling links each slide to its patient and block; mislabelling can cause a wrong diagnosis.

ID LG-HIS-0157 · Found a mistake? Report it
Q4EasyLab safety, equipment & museum

Which microscope gives a three-dimensional view of a specimen for grossing or dissection?

Answer: C. Stereo (dissecting) microscope

Stereo microscopes use two optical paths, one per eye, giving depth perception at low magnification.

ID LG-HIS-0159 · Found a mistake? Report it
Q5EasyLab safety, equipment & museum

The 'high-dry' objective on a standard light microscope has what magnification?

Answer: C. 40×

The 40× objective is the highest used without immersion oil. The 100× objective requires oil; 10× is low power.

ID LG-HIS-0255 · Found a mistake? Report it
Q6EasyLab safety, equipment & museum

To pull a paraffin block from the archive, a technician should search by:

Answer: C. The laboratory accession (surgical pathology) number

Blocks and slides are filed by unique accession number, which links to the patient record. Names and bed numbers are not unique or durable identifiers.

ID LG-HIS-0297 · Found a mistake? Report it
Q7EasyLab safety, equipment & museum

Kaiserling solutions are used for:

Answer: C. Preserving museum specimens with natural colour

Kaiserling fixatives and preservatives retain the natural colour of gross specimens displayed in pathology museums.

ID LG-HIS-0311 · Found a mistake? Report it
Q8EasyLab safety, equipment & museum

Unstained living cells in culture can be viewed with good contrast using:

Answer: B. Phase contrast microscopy

Phase contrast converts small differences in refractive index into differences in brightness, so live cells can be seen without staining. TEM requires fixed, sectioned material.

ID LG-HIS-0330 · Found a mistake? Report it
Q9EasyLab safety, equipment & museum

Which microscopic technique cannot be used to examine living cells?

Answer: C. Transmission electron microscopy

TEM needs a vacuum and fixed, ultrathin, heavy-metal-stained sections, so cells must be dead. Phase contrast, DIC and fluorescence can all image live cells.

ID LG-HIS-0331 · Found a mistake? Report it
Q10EasyLab safety, equipment & museum

A temperature log reads 38.2 °F (about 3.4 °C). This reading is typical of which laboratory equipment?

Answer: A. Refrigerator

38.2 °F converts to about 3.4 °C, within the 2–8 °C refrigerator range. Freezers run below 0 °C and incubators near 37 °C.

ID LG-HIS-0404 · Found a mistake? Report it
Q11MediumLab safety, equipment & museum

Kaiserling solutions used for museum specimens preserve natural colour. Their fixing agent is:

Answer: B. Formaldehyde

Kaiserling fixatives are formalin-based with potassium salts; picric acid stains tissue yellow.

ID LG-HIS-0100 · Found a mistake? Report it
Q12MediumLab safety, equipment & museum

A slide that focuses at 10× cannot be brought into focus with the 40× objective. The most likely cause is:

Answer: A. The slide is placed upside down on the stage

With the coverslip facing down, the slide thickness exceeds the short working distance of the 40× objective. Staining or smear thickness affects image quality but not the ability to focus.

ID LG-HIS-0257 · Found a mistake? Report it
Q13MediumLab safety, equipment & museum

Which piece of routine histology equipment does NOT depend on a controlled temperature to function?

Answer: D. Rotary microtome for paraffin blocks

Embedding centres, processors and flotation baths all hold wax or water at set temperatures. A standard rotary microtome is a mechanical cutting device used at room temperature.

ID LG-HIS-0280 · Found a mistake? Report it
Q14MediumLab safety, equipment & museum

In a phase contrast microscope, the annular diaphragm in the condenser must be aligned with which component?

Answer: C. The phase plate (ring) in the objective

Light passing through the condenser annulus must fall on the matching phase ring in the objective to create contrast. Prisms and polarizers belong to DIC and polarization microscopy.

ID LG-HIS-0335 · Found a mistake? Report it
Q15MediumLab safety, equipment & museum

Under polarized light, which structure appears dark because it is isotropic (non-birefringent)?

Answer: B. I-band of striated muscle

The I-band is isotropic and the A-band anisotropic, hence their names. Collagen and bone lamellae are birefringent.

ID LG-HIS-0338 · Found a mistake? Report it
Q16MediumLab safety, equipment & museum

In a tissue autoradiograph, the developed silver grains over labelled cells are best visualized as bright points against a dark background using which microscopy?

Answer: B. Dark-field

Dark-field illumination makes the light-scattering silver grains appear bright, so even small numbers are easily counted. Polarizing microscopy is for birefringent material such as crystals or amyloid.

ID LG-HIS-0365 · Found a mistake? Report it
Q17MediumLab safety, equipment & museum

Which clearing agent is most associated with skin sensitization after repeated use?

Answer: B. Limonene (citrus-based) reagents

D-limonene clearants oxidize to allergenic compounds and can cause contact sensitization with prolonged exposure. Xylene is mainly a neurotoxic and irritant hazard.

ID LG-HIS-0393 · Found a mistake? Report it
Q18MediumLab safety, equipment & museum

Under the OSHA formaldehyde standard, the 8-hour time-weighted average permissible exposure limit is:

Answer: C. 0.75 ppm

OSHA sets the 8-h TWA PEL at 0.75 ppm; 0.5 ppm is the action level and 2 ppm the 15-minute short-term limit.

ID LG-HIS-0406 · Found a mistake? Report it
Q19MediumLab safety, equipment & museum

For a cryostat in daily use, CAP accreditation expects routine decontamination at a defined interval; the commonly applied minimum is:

Answer: A. Weekly

Cryostats must be decontaminated at defined intervals (commonly at least weekly for daily use) and after known infectious cases, since freezing does not inactivate pathogens such as TB.

ID LG-HIS-0408 · Found a mistake? Report it
Q20HardLab safety, equipment & museum

A section stained mainly blue is photographed in bright field. Which colour filter will give the greatest contrast?

Answer: D. Yellow

A filter of the complementary colour is absorbed by the stained structures, making them appear dark against a bright background. A blue filter would make blue structures fade.

ID LG-HIS-0336 · Found a mistake? Report it